13 Owner’s Manual and Service Guide – PC & PCT Series
WARNING
OPERATING INSTRUCTIONS
To prevent unexpected vehicle movement or
unauthorized use, always turn the key switch to the OFF
position and remove key when the vehicle is not in use
Programmable Security Switch (Optional): SAFE-T-
LOCK™ is a programmable code switch,( Figure 5), which
prevents unauthorized use of the vehicle.
It is offered as an option, part
number EV-E901. The SAFE-T-
LOCK switch is installed in lieu of
the standard switch to control
access and operation of the vehicle
within the customer’s premises. It
can be pre-installed at time of
order, or purchased separately to
upgrade existing vehicles.
The STL1000 switch allows plant and facility managers to
input up to 99 different users/drivers to track vehicle usage.
If an accident occurs, or the vehicle is damaged, the
manager can easily identify the last operator. The switch
also features an internal clock that records "on" hours and
notifies the operator when the 250-hour mark is reached.
Each user can select a four- to eight-digit personal access
code and a separate supervisor user menu programs the
unit. The switch will provide the last user ID code when
prompted by the supervisor. In operation, only users with
active ID codes can operate the vehicle, virtually eliminating
all unauthorized use, the company said.
The switch operates in a voltage range from 9 to 120 volts
DC and is enclosed in an IP65 rated housing. Two internal
LEDs indicate operational status - red indicates an error or
lock mode and green indicates key press or touch is active.
The unit also provides user feedback with key beep and
error tones.
Step-by-Step Programming Instructions:
1 Log onto the Supervisor Mode. Press 0 0 1 2 3 4
ENTER. Red and Green LED flashes along with an up tone
beep indicate you are in the Supervisor Mode and ready to
enter a Supervisor Mode menu.
Note: As you enter each Supervisor Mode menu, the number
of Red LED flashes will correspond to the menu number. For
example, one Red LED flash for menu 1, two Red LED
flashes for menu 2, etc.
Before changing the Supervisor PIN, you are first going to
add User locations. For this example you will check on and
add User location 01 as well as more User locations as
required. To do this you must go into the Add / Delete User
Menu.
2 Go into Add / Delete User Menu. Press 2 ENTER. There
will be a beep along with two Red LED flashes indicating you
are in Menu 2. Press 0 1 ENTER. If there is a Red flash and
a low beep, it indicates that user location 01 has already
been assigned. To remove location 01, press ENTER again.
This will delete the location from use.
Add location 01. Press 0 1 ENTER. You should now get a
Green flash along with an up tone beep indicating the
location is ready to be added or assigned to a user. Press
ENTER. You will get a Green LED flash along with a beep.
The user location has been added.
At this point you can, in the same way, check on and add
more user locations.
Before leaving Menu 2, check to make sure that location 01
and any others have been added. Press 0 1 ENTER. There
should be a Red LED flash along with a low tone beep
indicating the location has been assigned to the user. Check
any other locations you’ve added the same way. A Red flash
along with a low tone beep means the location has been
assigned. A Green flash along with an up tone beep means
the location is not assigned.
3 Go out of Menu 2. Press CE. The switch will indicate you
are back in Supervisor Mode. Press CE again to go out of
Supervisor Mode. (CE can be pressed several times to make
sure you are completely clear and ready to enter the next
mode.)
4 Log onto the User Mode. Press 0 1 1 2 3 4 ENTER. The
switch will close and the Green LED will flash at a slow rate.
5 Change User PIN. First decide on a new PIN. In this
example
e use 5 4 3 2 1. Press 1, ENTER. (This puts you in the
Change User PIN Menu.) Note that the switch will open
when you go into this menu.
Note: The User has 1 minute after logging on the User Mode
to use menu 1 before the menu function is locked out until
the next User log on.
Press 5 4 3 2 1 ENTER, again press 5 4 3 2 1 ENTER. The
switch will indicate that the new PIN has been accepted.
6 Use the new PIN to close the switch. Press 0 1 5 4 3 2 1
ENTER. The switch will close. Press ENTER to open the
switch and go out of User Mode. (Since this is an example,
you may want to set the PIN for User location 01 back to the
1 2 3 4 default.)
7 Log back onto the Supervisor Mode to change the
Supervisor PIN. Press 0 0 1 2 3 4 ENTER. Press 1 ENTER
to go into the Change Supervisor PIN Menu. The red LED
will flash once. Now just you did in the User Mode, put the
new PIN in twice and enter each time. Example: Press 5 4 3
2 1 ENTER, again 5 4 3 2 1 ENTER. The switch will give an
indication that the PIN was changed.
FIGURE 5
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 40 41

Comentarios a estos manuales

Sin comentarios

Avaya VisAbility Management Suite 1.0 Advanced Converged Management Offer podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Nie Avaya VisAbility Management Suite 1.0 Advanced Converged Management Offer.
Dostarczamy 1 pdf podręczników Avaya VisAbility Management Suite 1.0 Advanced Converged Management Offer do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika






Więcej produktów i instrukcji dla Nie Avaya

Modele Rodzaj dokumentu
BoSS 3.1 Uwaga   Avaya BoSS 3.1 Release Notes, 4 strony
1400 Series DCP phones Instrukcja Użytkownika   Avaya 1400 Series DCP phones User's Manual, 1 strony
ipView SoftBoard BCM Rls 6.0 Instrukcja Użytkownika   Avaya ipView SoftBoard BCM Rls 6.0 User's Manual, 54 strony
B169 Uwaga   Avaya B169 Release Notes, 6 strony
Business Series Terminals - BST Instrukcja Użytkownika   Avaya Business Series Terminals - BST User's Manual, 1 strony
HSSI Net Module in an ASN Platform Instrukcja Użytkownika   Avaya HSSI Net Module in an ASN Platform User's Manual, 38 strony
MultiSite Administration Release 2.1 Configuration Instrukcja Użytkownika   Avaya MultiSite Administration Release 2.1 Configuration Configuration manual, 28 strony
16CC Instrukcja Użytkownika   Avaya 16CC User's Manual, 1 strony
1140E Podręcznik Użytkownika   Avaya 1140E User Guide, 216 strony
EE Call Detail Recording System Instrukcja Użytkownika   Avaya EE Call Detail Recording System User's Manual, 56 strony
DECT Handset 4060 Podręcznik Użytkownika   Avaya DECT Handset 4060 User Guide, 172 strony
Sync/Ethernet Link Modules in BN Platforms Instrukcja Użytkownika   Avaya Sync/Ethernet Link Modules in BN Platforms User's Manual [en] , 58 strony
BCM450 Przewodnik Konfiguracji   Avaya BCM450 Configuration Guide, 34 strony
2402 Telephone Instrukcja Użytkownika Avaya 2402 Telephone User's Manual, 2 strony
1140E Podręcznik Użytkownika   Avaya 1140E User Guide, 198 strony
Data Migration Manager Version 1.1.5 Uwaga   Avaya Data Migration Manager Version 1.1.5 Release Notes, 4 strony
BayRS and BCC Software Version 15.4.2.2 Fixed Anomalies Instrukcja Użytkownika   Avaya BayRS and BCC Software Version 15.4.2.2 Fixed Anomalies User's Manual, 1 strony
IW1 Instrukcja Użytkownika   Avaya IW1 User's Manual, 43 strony
1140E Instrukcja Użytkownika   Avaya 1140E Product Bulletin, 15 strony
ipView Software Wallboard Instrukcja Użytkownika   Avaya ipView Software Wallboard User's Manual, 30 strony